家庭配电箱安装注意事项:
Precautions for installation of family distribution box:
1、家庭配电箱分金属外壳和塑料外壳两种,按照结构分类为明装式和暗装式两种,必须保证箱体的完整性。
1. The family distribution box is divided into two kinds of metal shell and plastic shell. According to the structure, it is classified into two types: the clear and the dark. It is necessary to ensure the integrity of the box.
2、家庭配电箱的箱体内接线汇流排应分别设立零线、保护接地线、相线、绝缘性能需良好。
2. It is necessary to set up zero line, protect grounding wire, phase line and insulation performance in the cabinet of the cabinet of the family distribution box.
3、空气开关的安装座架应光洁无阻并有足够的空间,应安装在干燥、通风部位,且无妨碍物,方便操作。
3. The mounting frame of the air switch should be clean and unobstructed and have enough space. It should be installed in the dry and ventilated parts, and without hindrance, it is convenient to operate.
4、配电箱埋入墙体时应垂直、水平,边缘留5~6毫米的缝隙,配电箱内的接线应规则、整齐,端子螺丝必须紧固。
4. When the distribution box is buried in the wall, it should be vertical, horizontal, and the edge is 5~6 millimeter. The wiring in the distribution box should be regular and neat, and the terminal screws must be fastened.
5、家庭配电箱配电箱不宜安装过高,一般安装标高为1.8米,以便操作;进配电箱的电管必须用锁紧螺帽固定。
5. The distribution box of the family distribution box should not be installed too high, and the general installation is 1.8 meters high for operation, and the pipe of the power distribution box must be fixed with a locking nut.
6、各回路进线必须有足够长度,不得有接头,安装后标明各回路使用名称。
6, the loop line must have enough length, no joint, and the use name of each loop after installation.
7、安装完成后要将配电箱内清理干净,保证箱内五残留物,以防使用过程中造成故障。
7. After the installation is completed, we should clean up the distribution box and guarantee the five residue in the box, so as to prevent the failure in the process of use. |